TS 750/TS 150

    Specifications

    Cable

    Workpiece touch probe

    TS 7501)

    TS 150

    Probing accuracy

    ±1 μm with use of the T434 standard stylus

    ±5 μm with use of the T404 standard stylus

    Probe repeatability

    Repeated probing from
    one direction

    2 s 0.25 μm at a probing speed of 1 m/min

    2 s 1 μm at a probing speed of 1 m/min

    Probing force

    Axial: ? 1.5 N

    Radial: ? 0.2 N

    Axial: ? 7 N

    Radial: ? 1 N

    Deflection of probe contact

    5 mm in all directions (with stylus length L = 40 mm)

    Deflection forces

    Axial: ? 8 N

    Radial: ? 1 N

    Probing speed

    3 m/min

    Protection EN 60529

    IP68

    Operating temperature

    10 °C to 40 °C

    Storage temperature

    –20 °C to 70 °C

    Mass without base

    ? 0.1 kg

    ? 0.1 kg

    Fastening*

    • Base with M22x1 thread and axial cable outlet
    • Base with three M3 screws and axial cable outlet
    • Base with four M3 screws and axial cable outlet
    • Touch-probe extension with M16x1 thread

    Electrical connection*

    Two-pole sliding contact on the mounting base

    Signal transmission

    Cable: ≤ 25 m

    Supply voltage2)

    DC 15 V to 30 V at 85 mA (without load)

    Output signals2)

    Trigger signals S and S (square-wave signal and its inverted signal)

    Floating trigger output

    HTL signal levels2)

    UH 20 V at –IH 20 mA

    UL 2.8 V at –IL 20 mA

    at rated voltage of DC 24 V

    * Please select when ordering

    1) Available as a prototype; orderable only after consultation

    2) Via UTI 150